Parallel (Centronics)
The parallel port is a standard 36-pin Centronics. Pin
assignments are as follows:
Pin
Direction
Definition Pin Direction
Definition
1
In /STROBE
13
Out SELECT
2
In Data1
14,15
NC
3
In Data 2
16
- Ground
4
In Data3
17
- Ground
5
In Data4
18NC
6
In Data5
19~30
- Ground
7
In Data6
31
NC
8
In Data7
32
Out /Fault
9
In Data8
33~36
- NC
10
Out /ACK
11t
Out BUSY
12
Out PE
Auto Polling
Both the serial port and parallel port of this printer can be
activated at the same time, i.e the printer can simultaneously
communicate with two PCs via different ports. However as no port
contention is made for this printer, if both PCs transmit data at the
same time the data may become damaged in the receiving buffer.
77
Appendix I - Installing Dispenser Kit
1. Turn off the printer power and unplug the printer.
2. Unwrap the dispenser kit and take out screws, the shaft,
the plastic roller, the dispenser bar, the direction label, and
the peeler sensor cable.
Top Cover
3. Take off the top cover of the printer.
4. The peeler sensor cable has a sensor board at one end
and a connector at the other end.
5. Mount the two little holes of the sensor board on the two
spines at left upper corner inside the top cover, keeping
the cable at the left.
6. Route the peeler sensor cable through the guides along
the left side of the top cover.
7. Fix the sensor cable and sensor board with Loctite-444
instant adhesive or equivalent.